Doubel Combustion Chamber

All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.

Read More

High Temperature Incineration

Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.

Read More

Get Lastest News

There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation

Read More

Nanjing Clover Medical Technology Co.,Ltd.

Email: [email protected] | Tel: +86-25-8461 0201

Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.

Latest Post

INDUSTRIAL INCINERATOR

-Size requirement for the incinerators is 750-850 kg capacity
-The burn rate should be 80-100 kg/hour
-The primary chamber should have an operating temperature of 900-1200 degree C
-The incinerator should have a high temperature secondary chamber and 2 second gas retention time at 850-1150 degree C so that it is suitable for high risk materials
-The incinerator should have temperature monitoring and thermostat control for ease of operation and assurance of burn temperature to confirm correct operation
-The incinerator should be capable of burning any of the hazardous wastes listed in the subsequent section
-The incinerator should be capable of burning diesel oil and should include a large fuel tank (10-500 litres) and generator (3-40 kV) set that can be carried on the trailer with the incinerator so that the unit requires no external electrical power supply
-The incinerator should be trailer mounted so that it is a portable unit
Hazardous Waste to be Incinerated:
Hazardous solid chemical:
Different types of combustible solids, used textiles, grease and toner, cartridges, chemicals for water purification and photographic consumables and plastic material, empty plastic/metal cans that still contain remnant hazardous materials, oil absorbent.
Hazardous liquid chemical:
Mainly different types of Acid, Paint, varnish, Acetone, White Spirit Aromatic-less Solvents, Synthetic Liquid for Break Systems, Aircraft De-icing Liquid, Hydraulic and Compressor oil, Freon, used in some older refrigeration units, Insecticide liquid/spray, air refresh spray and other similar chemicals
Contaminated Fuel:
Mainly diesel or gasoline contaminated by water or solvents
Used and/or Contaminated oil:
Used motor oils and/or mineral oils unfit for their originally intended use. Mainly motor and gearbox oil (approximately 80%) contaminated by a mixture of white spirit and acetone (approximately 5%), hydraulic liquid (approximately 5%)
Contaminated Water:
Waste oils/water, leaches, hydrocarbons/water mixtures, emulsion and leachate.
Contaminated soil:
Soil populated by oil, fuel or chemicals
Contaminated soil populated by chemicals that has to be recycled in landfill
Contaminated soil – treated and replaced on site.
Oil Contaminated solids:
Rags, Absorbents, cardboard, oil and fuel filters, air filters are not consider as hazardous materials
Electronic waste:
Waste electrical or electronic appliances or assemblies, including printed circuit boards, containing toxic material and/or heavy emitting low radiation.
Used battery cells:
Dry battery, UPS battery or other types, unsorted waste batteries/battery cells, containing materials that are hazardous
Used lead-acid batteries:
Waste lead acid batteries, drained/un-drained, and whole or crushed
Hazardous medical waste:
Clinical and related waste, arising from medical, nursing or similar practices and waste generated in clinics during the investigation or treatment of patients (bio hazards)
Expired drugs solid:
Waste pharmaceuticals, drugs and medicines, including sensitive medicines
Expired drugs liquid:
Waste liquid pharmaceuticals, different type liquid chemicals for treatment, medical grease and paraffin based expired medicines.
Expired and/or contaminated food:
Spoiled fresh food or unusable MRE’s (Meal Ready to Eat – dry food)

Bio-Medical Waste Incinerator

We have the pleasure to inform you that one of our customer interested to import Bio-Medical Waste Incinerator, capacity 30 kgs/hr operating type Electric operated or LPG/Diesel 
SMART ASH INCINERATOR
-Size requirement for the incinerators is that the unit works with a 55 gallon open ended steel drum
-the unit should operate with no fuel and use only 120V or 220V electricity for the blowers
-The unit should be capable of burning oil contaminated wastes and medical wastes with a moisture content of 0-15%
-Each unit should come with two steel drums, so that a spare drum is available
Please quote urgently a medical waste incinerator of aprox. 25 to 50 kg/day for a 130 bed hospital, or a incinerating volume of 1.25 cubic meters per cycle.I want to start providing a service to the local hospitals and clinics in my area, where I can dispose of there medical waste via the route of incineration.

Say Good Bye with our Old Friends- My Lovely Pet Cremation

Amazing, Babe, Baby Bear, Honey Cakes… do you every have a dog or cat name same as this?

I watch TV with my dog Sanmao, i always walk with her after dinner, i buy dog food and toy from Taobao. Every pet owner do something like this because pet dogs, cats are always our best friends.

 

Some day, lovely pet have to leave us. You may cry, you lost a best friend, you lost something in your heart, you still remember

what’s Incinerators

Incinerator, incineration equipment to burn material you want to burn. most of time, Incinerator for waste burning, including solid waste, liquid waste and gas waste. the Incinerator fuel including oil, gas, coal, wood, etc. the fuel function for start burn, keep waste burn or only keep burn itself to get high temperature. Incinerator request 1/2/3/more Incinerator chamber, the first chamber for waste and some time, there are 2 even if 3 first chamber(first chamber union) for waste. the senondary chamber for the gas/smoke from first chamber and the function for enviromental protection. the part is necessary because we not only burn the waste, but also for the result we burn the waste. for large capacity Incinerator, after the 1/2/3 combustion chambers, there are some part for emission treatment, this are not burning parts, they are only for smoke treatment. the function including Desulfurization, Deacidification, Ash remove, Defogging, Heat recovery, Production hot water, Hot gas for waste pre-dry, etc. at the end, the smoke will output in to environment.

Double Combustion Chamber Incinerators

● Double Combustion Chamber
All waste incinerator design with double combustion chamber. High Temperature, Smoke Treatment,No black smoke, Environmentally friendly. 
● Containerized Mobile Incinerator
The incinerator mounted in ISO Container before leave factory, free-installation, no incineration house build construction,movable by truck. 
● Family Pet Dog&Cat Cremation
Special design with movable platform, combustion chamber material and custom made for pets crematory business. 
● Installation and Commissioning
Clover’s engineers instal,train for most of the region and free-cost train in our factory. 

Clover's Social Media