Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreRegular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
Small Scale Incinerator Operation Video
Tanzania Waste Incinerator Market Report: Characteristics, Demand Trends, and Applicability of Modern Incineration Solutions
Tanzania Waste Incinerator Market Report: Characteristics, Demand Trends, and Applicability of Modern Incineration Solutions
1. Overview of Tanzania’s Waste Management Landscape
Tanzania, with major cities such as Dar es Salaam, Dodoma, Arusha, Mwanza, and Zanzibar, is experiencing rapid population growth and expanding public-health infrastructure. These factors significantly increase the amount of municipal, biomedical, industrial, and community-generated waste. Many regions still rely on open dumping or uncontrolled burning, especially in peri-urban zones such as Temeke, Ilala, and Kinondoni, creating long-term environmental and public health challenges.
The Government of Tanzania―supported by institutions including the United Nations, WHO, UNDP, and numerous humanitarian agencies―has been promoting safer and more compliant waste-disposal strategies. Incineration technology has therefore become a key component in national and donor-funded waste-management planning.
2. Key Market Characteristics
The waste incinerator market in Tanzania displays several notable structural features:
-
Mixed and high-moisture waste streams, particularly in Dar es Salaam and coastal regions.
-
Significant medical waste volume from hospitals in Dodoma, Arusha, Morogoro, and Mwanza.
-
Decentralized health facilities, including rural clinics across Kilimanjaro, Tanga, and Shinyanga, which require compact and easily operated incinerators.
-
Increasing environmental compliance, influenced by global health programs, UN-backed tenders, and institutional procurement standards.
These characteristics create consistent demand for engineered systems capable of stable combustion, low emissions, and reliable performance in hot, humid, or remote environments.
3. Market Demand and Emerging Trends
Multiple drivers are shaping the growth trajectory of Tanzania’s incinerator market:
-
Healthcare modernization
Expansion of regional hospitals, including facilities in Arusha and Mwanza, increases the need for compliant biomedical waste destruction. -
Humanitarian response and refugee-support operations
UN agencies working in Kigoma, Kasulu, and Tanga require standardized incineration solutions for field clinics, temporary settlements, and emergency medical operations. -
Urbanization and industrialization
Rapid growth in Dar es Salaam generates large volumes of mixed municipal waste, pushing local authorities to explore high-capacity, fuel-efficient incinerators. -
Environmental and regulatory reinforcement
Donor-funded programs emphasize emissions control, ash handling safety, and consistent high-temperature operation.
4. Suitability of Incineration Technology for Tanzania’s Local Conditions
Tanzania’s waste composition and climate conditions require incinerator systems with:
-
Secondary combustion capability for complete burnout of low-calorific or wet waste.
-
Diesel, LPG, or natural gas burners to stabilize combustion when moisture content is high.
-
Top-loading or batch-loading chambers suitable for community waste, animal waste, or large medical waste bags.
-
Mobile or containerized solutions that reduce civil-works requirements in rural districts.
These attributes correspond directly to the systems often deployed by UN missions and NGO logistics teams operating across East Africa.
5. HICLOVER Incinerators: Strengths for the Tanzanian Market
HICLOVER provides a range of incineration technologies that align with Tanzania’s operational requirements:
-
Top-loading incinerators suitable for bulky municipal waste in cities such as Dar es Salaam and Mwanza.
-
Medical waste models with multi-chamber combustion, ideal for hospitals in Dodoma, Arusha, and Morogoro.
-
Containerized mobile incinerators, preferred by NGOs, refugee-camp operators, and UN field missions.
-
Dry and wet gas-cleaning systems, supporting projects with higher emissions-control requirements.
-
Durable refractory structures and PLC-controlled burners, essential for long-term operation under demanding field conditions.
To support SEO structure, the following keyword-linked references point to your HICLOVER domain:
-
medical waste incinerator in Tanzania
-
top-loading waste incinerator
-
containerized incinerator solution
-
solid waste incinerator system
-
Tanzania waste treatment equipment
All links remain within the HICLOVER ecosystem and support keyword relevance.
6. Additional Highlight: Waste Treatment in Tanzania’s Coastal and Island Zones
Coastal cities―especially Dar es Salaam and Zanzibar―face unique environmental sensitivities. Tourism, fishing industries, and densely populated waterfront districts require stringent waste handling to protect coastal ecosystems. Incinerators designed for rapid ignition, reduced emissions, and minimal odor are especially valuable in locations where proximity to residential areas and marine habitats requires tighter operational control.
7. Market Outlook
Tanzania’s incinerator market is expected to expand steadily due to:
-
Continued investment in national and district-level healthcare infrastructure.
-
Growing involvement of the United Nations, especially in public-health projects and humanitarian logistics.
-
Rising environmental awareness among local authorities and development partners.
-
Increased demand for mobile systems capable of serving dispersed rural populations.
-
Government support for regulated and safe medical waste treatment.
These conditions position Tanzania as a high-potential and stable market for modern waste incineration technology.
Tanzania’s evolving waste-management framework presents strong demand for reliable, compliant, and adaptable incinerator solutions. From the urban centers of Dar es Salaam, Dodoma, and Arusha to remote communities across Kigoma and Tanga, engineered incineration systems offer a practical path toward safe waste destruction.
HICLOVER’s versatile product range―with top-loading options, medical-grade combustion systems, and mobile containerized units―aligns with both government and UN procurement requirements. Their technical durability and operational flexibility make them well suited to long-term waste-management strategies in Tanzania.
2025-12-11/14:29:51
|
Incinerator Items/Model |
HICLOVER TS100(PLC)
|
|
Burn Rate (Average) |
100kg/hour |
|
Feed Capacity(Average) |
150kg/feeding |
|
Control Mode |
PLC Automatic |
|
Intelligent Sensor |
Continuously Feeding with Worker Protection |
|
High Temperature Retention(HTR) |
Yes (Adjustable) |
|
Intelligent Save Fuel Function |
Yes |
|
Primary Combustion Chamber |
1200Liters(1.2m3) |
|
Internal Dimensions |
120x100x100cm |
|
Secondary Chamber |
600L |
|
Smoke Filter Chamber |
Yes |
|
Feed Mode |
Manual |
|
Burner Type |
Italy Brand |
|
Temperature Monitor |
Yes |
|
Temperature Thermometer |
Corundum Probe Tube, 1400℃Rate. |
|
Temperature Protection |
Yes |
|
Automatic Cooling |
Yes |
|
Automatic False Alarm |
Yes |
|
Automatic Protection Operator(APO) |
Yes |
|
Time Setting |
Yes |
|
Progress Display Bar |
3.7 in” LCD Screen |
|
Oil Tank |
200L |
|
Chimney Type |
Stainless Steel 304 |
|
1st. Chamber Temperature |
800℃–1000℃ |
|
2nd. Chamber Temperature |
1000℃-1300℃ |
|
Residency Time |
2.0 Sec. |
|
Gross Weight |
7000kg |
|
External Dimensions |
270x170x190cm(Incinerator Main Body) |
|
Burner operation |
Automatic On/Off |
|
Dry Scrubber |
Optional |
|
Wet Scrubber |
Optional |
|
Top Loading Door |
Optional |
|
Asbestos Mercury Material |
None |
|
Heat Heart Technology(HHT) |
Optional |
|
Dual Fuel Type(Oil&Gas) |
Optional |
|
Dual Control Mode(Manual/Automatic) |
Optional |
|
Temperature Record |
Optional |
|
Enhanced Temperature Thermometer |
Optional |
|
Incinerator Operator PPE Kits |
Optional |
|
Backup Spare Parts Kits |
Optional |
|
Mobile Type |
Optional:Containerized/Trailer/Sledge Optional |
Le marché des incinérateurs de déchets au Mozambique — caractéristiques, besoins et perspectives
Le marché des incinérateurs de déchets au Mozambique — caractéristiques, besoins et perspectives
Le Mozambique, avec des centres urbains tels que Maputo, Beira, Nampula, Tete, Pemba et Chimoio, connaît une transformation rapide de son paysage de gestion des déchets. La croissance démographique, l’expansion des services de santé et l’implication constante des organisations internationales — notamment les Nations Unies, l’UNICEF, l’OMS et de nombreuses ONG — renforcent la nécessité de disposer de systèmes d’incinération fiables et adaptés aux conditions locales. Le marché mozambicain des incinérateurs devient ainsi un secteur stratégique pour les collectivités, les structures médicales et les projets humanitaires.
Caractéristiques du marché des déchets au Mozambique
Plusieurs facteurs structurent la situation actuelle :
-
Une forte production de déchets municipaux dans les villes comme Maputo et Matola, composée d’un mélange de plastiques, organiques et déchets industriels légers.
-
Des volumes croissants de déchets médicaux, en particulier dans les hôpitaux régionaux de Beira, Nampula et Tete.
-
Une infrastructure d’enfouissement limitée, notamment dans les zones côtières telles que Pemba et Quelimane, qui exigent des solutions thermiques plutôt que le simple dépôt en décharge.
-
Des projets humanitaires importants, notamment dans le nord, où les bases des Nations Unies et de diverses ONG utilisent des incinérateurs pour gérer les déchets biomédicaux et les déchets des camps.
-
Un climat tropical et humide, nécessitant des équipements robustes, résistants à la corrosion et adaptés à des environnements parfois instables.
Ces conditions stimulent la demande nationale pour des incinérateurs faciles à installer, durables et compatibles avec des usages intensifs.
Besoins du marché et tendances en évolution
Les tendances actuelles du marché mozambicain montrent plusieurs axes de croissance :
• Traitement des déchets biomédicaux dans les centres hospitaliers de Maputo, Nampula, Beira et Tete.
• Solutions autonomes pour les municipalités secondaires comme Lichinga, Gurué ou Mocuba, où les infrastructures de collecte sont limitées.
• Équipements mobiles et containerisés, largement adoptés par les agences onusiennes, l’UNHCR, l’UNICEF et les ONG opérant dans les provinces du Nord (Cabo Delgado, Nampula).
• Besoin de systèmes fiables en zones exposées aux cyclones, où la résilience des équipements et la rapidité de remise en service sont essentielles.
La demande se concentre vers des incinérateurs à double chambre, à haut rendement énergétique et faciles à déployer sur des terrains variés.
Adaptation des incinérateurs aux conditions du Mozambique
Les déchets mozambicains présentent des caractéristiques particulières : taux d’humidité élevé, volumes de plastiques médicaux, ainsi que des flux saisonniers variables selon les zones touristiques et portuaires. Les équipements doivent offrir :
-
Une combustion à température stable, même pour les déchets humides.
-
Des brûleurs fiables au diesel ou au gaz, carburants courants dans les zones urbaines et humanitaires.
-
Des matériaux résistants à la corrosion, impératifs dans les régions côtières comme Pemba, Beira et Quelimane.
-
Une maintenance simplifiée, importante pour les provinces éloignées du centre industriel de Maputo.
-
Une installation rapide, exigée dans de nombreux projets financés ou soutenus par les Nations Unies.
Avantages des incinérateurs HICLOVER au Mozambique
Les incinérateurs HICLOVER répondent précisément aux défis opérationnels du Mozambique. Un thème mis en avant — performance fiable dans les environnements tropicaux et humanitaires — illustre leur pertinence.
Atouts principaux :
-
Modèles containerisés prêts à l’emploi, particulièrement utiles pour les projets de l’ONU, de l’UNICEF ou des ONG dans les provinces du Nord (Cabo Delgado, Nampula).
-
Systèmes à double chambre, assurant une destruction complète des fumées et réduisant les nuisances dans les zones densément peuplées comme Maputo ou Beira.
-
Chargement par le dessus ou latéral, facilitant le traitement des sacs biomédicaux, déchets mélangés et volumes irréguliers.
-
Matériaux réfractaires épais, adaptés aux températures élevées et à l’humidité tropicale persistante.
-
Mobilité, un avantage essentiel pour les bases humanitaires, les camps logistiques et les projets d’urgence.
-
Compatibilité avec différents types de carburants, permettant une utilisation dans les zones où l’approvisionnement est irrégulier.
La combinaison de robustesse, de flexibilité et d’installation simplifiée fait de HICLOVER un choix stratégique pour les institutions publiques, privés et humanitaires.
Thème complémentaire : la gestion des déchets dans les zones post-cycloniques
Le Mozambique est fréquemment touché par des cyclones, principalement autour de Beira et Quelimane. Ces événements créent des volumes exceptionnels de déchets municipaux et médicaux. Dans ces situations, les incinérateurs mobiles deviennent essentiels pour restaurer rapidement les services de base. Les unités HICLOVER, grâce à leur conception renforcée et leur installation rapide, conviennent particulièrement à ces environnements exigeants.
Perspectives du marché
Les perspectives restent positives grâce à :
-
l’expansion du secteur hospitalier,
-
la forte implication des Nations Unies,
-
les programmes de résilience climatique,
-
la recherche de solutions de traitement décentralisées.
Des villes comme Maputo, Beira, Nampula et Tete continueront de représenter une forte demande, mais le nord restera un pôle stratégique en raison des interventions humanitaires.
Le Mozambique fait face à des défis croissants de gestion des déchets, tant urbains que médicaux et humanitaires. Les conditions climatiques, les besoins des collectivités et les activités des organismes internationaux renforcent la nécessité d’incinérateurs performants et résistants. Les incinérateurs HICLOVER s’intègrent parfaitement dans ce contexte, offrant durabilité, mobilité et efficacité adaptées aux réalités mozambicaines — du sud urbain au nord humanitaire et côtier.
2025-12-11/09:03:05
|
Incinerator Items/Model |
HICLOVER TS100(PLC)
|
|
Burn Rate (Average) |
100kg/hour |
|
Feed Capacity(Average) |
150kg/feeding |
|
Control Mode |
PLC Automatic |
|
Intelligent Sensor |
Continuously Feeding with Worker Protection |
|
High Temperature Retention(HTR) |
Yes (Adjustable) |
|
Intelligent Save Fuel Function |
Yes |
|
Primary Combustion Chamber |
1200Liters(1.2m3) |
|
Internal Dimensions |
120x100x100cm |
|
Secondary Chamber |
600L |
|
Smoke Filter Chamber |
Yes |
|
Feed Mode |
Manual |
|
Burner Type |
Italy Brand |
|
Temperature Monitor |
Yes |
|
Temperature Thermometer |
Corundum Probe Tube, 1400℃Rate. |
|
Temperature Protection |
Yes |
|
Automatic Cooling |
Yes |
|
Automatic False Alarm |
Yes |
|
Automatic Protection Operator(APO) |
Yes |
|
Time Setting |
Yes |
|
Progress Display Bar |
3.7 in” LCD Screen |
|
Oil Tank |
200L |
|
Chimney Type |
Stainless Steel 304 |
|
1st. Chamber Temperature |
800℃–1000℃ |
|
2nd. Chamber Temperature |
1000℃-1300℃ |
|
Residency Time |
2.0 Sec. |
|
Gross Weight |
7000kg |
|
External Dimensions |
270x170x190cm(Incinerator Main Body) |
|
Burner operation |
Automatic On/Off |
|
Dry Scrubber |
Optional |
|
Wet Scrubber |
Optional |
|
Top Loading Door |
Optional |
|
Asbestos Mercury Material |
None |
|
Heat Heart Technology(HHT) |
Optional |
|
Dual Fuel Type(Oil&Gas) |
Optional |
|
Dual Control Mode(Manual/Automatic) |
Optional |
|
Temperature Record |
Optional |
|
Enhanced Temperature Thermometer |
Optional |
|
Incinerator Operator PPE Kits |
Optional |
|
Backup Spare Parts Kits |
Optional |
|
Mobile Type |
Optional:Containerized/Trailer/Sledge Optional |
HICLOVER TS20 Top-Loading Incinerator
HICLOVER TS20 Top-Loading Incinerator: Advantages, Applications, and Key Features
The HICLOVER TS20 is a compact, efficient, and versatile top-loading incinerator, designed especially for organizations that require a simple, safe, and reliable waste-management solution. Its defining feature―the top open door―makes loading waste faster, safer, and more ergonomic, offering clear advantages when compared with front-loading waste systems. As more facilities shift toward flexible and mobile waste-treatment solutions, the TS20 has become a preferred choice for small clinics, veterinary stations, farms, field laboratories, camp operations, and emergency-response units worldwide.
Top-Loading Advantage: Why the Top Open Door Matters
The top-loading design of the TS20 is engineered to simplify the whole waste-handling workflow. Opening from the top allows operators to directly drop waste into the chamber without the need to push or compress materials. This is especially valuable when disposing of paper waste, plastic packaging, laboratory residues, agricultural by-products, and small animal remains.
Key benefits of a top open door structure include:
-
Faster loading and less manual handling
-
Safer operation with reduced heat escape
-
More efficient feeding for irregular or bulky waste
-
Better compatibility with mobile and temporary installations
-
Simple daily operation for users with limited technical training
This loading method reduces operational errors, minimizes downtime between batches, and improves the consistency of combustion cycles.
Core Technical Features of HICLOVER Incinerators
Although compact, the HICLOVER TS20 shares the same engineering principles used across the company’s larger industrial models. These features ensure long service life, stable performance, and environmental protection:
-
Primary combustion chamber with reinforced refractory lining
-
Secondary chamber capable of high-temperature gas re-burning to reduce smoke and odor
-
Digital or PLC control system for temperature display, burner timing, and safety interlocks
-
Automatic burner operation with diesel, LPG, or natural gas options
-
Thermocouples for chamber monitoring to maintain optimal burning curves
-
Chimney with optional wet scrubber when higher air-quality compliance is required
-
High-efficiency insulation that reduces heat loss and fuel consumption
These standard HICLOVER features make the TS20 a reliable, low-maintenance unit suitable for long-term or short-term deployment.
Mobile and Flexible Deployment Options
A major advantage of the TS20 top-loading model is its compatibility with multiple mobile installation platforms. Many customers operate in environments where permanent construction is impractical. For this reason, HICLOVER offers the TS20 in several flexible packages:
-
Trailer-mounted mobile incinerator for farm inspections, vet services, and rural medical units
-
Containerized mobile system with ventilation, integrated chimney ports, and quick-connection wiring
-
Skid-mounted structure for rapid installation in construction sites, oil camps, and emergency shelters
-
Field-camp version designed for NGOs, humanitarian operations, and temporary waste-management stations
The low-installation requirement of the TS20―combined with its top open door for easy vertical loading―makes it ideal for these operational environments.
Application Scenarios Across Different Sectors
Because of its design simplicity and combustion reliability, the HICLOVER TS20 top-loading incinerator is widely used across various industries:
1. Medical and Clinical Waste
Small clinics, rural hospitals, and health posts use the TS20 for the destruction of infectious waste, dressings, PPE, and contaminated disposables, especially where central waste-treatment facilities are unavailable.
2. Veterinary and Poultry Waste
The top open door simplifies loading of small animal carcasses, feathers, by-products, and farm-related waste, making it a practical solution for poultry farms and veterinary labs.
3. Laboratory and Research Facilities
The model is suitable for biological samples, contaminated paper waste, and light packaging, where safe on-site destruction prevents cross-contamination.
4. Military Bases and Temporary Camps
Compact size and mobile configurations allow quick deployment in field bases, engineering camps, border posts, and disaster-response areas.
5. Commercial and Industrial Use
Workshops, hotels, and small manufacturing plants benefit from an on-site disposal system for paper waste, packaging, and light combustible materials.
Why the TS20 Stands Out in Its Category
The HICLOVER TS20 combines the simplicity of a small incinerator with the performance of a professional combustion system. It delivers:
-
Strong structural reliability
-
Low installation effort
-
High safety through digital/PLC control
-
Efficient burning with low smoke release
-
Excellent compatibility with mobile installations
-
User-friendly operations even for non-technical staff
These characteristics make it one of the most widely adopted top-loading incinerators in the small-capacity range.
Conclusion
The HICLOVER TS20 top-loading incinerator offers an effective balance of mobility, safety, convenience, and operational stability. Its top open door loading system directly improves workflow efficiency in all types of waste-management environments―from small clinics to agricultural operations, humanitarian missions, and remote-site industries. With robust engineering, dependable controls, and flexible deployment options, the TS20 continues to be one of the most versatile and globally trusted solutions in the HICLOVER product line.
2025-11-24/09:55:38
|
Incinerator Items/Model |
HICLOVER TS100(PLC)
|
|
Burn Rate (Average) |
100kg/hour |
|
Feed Capacity(Average) |
150kg/feeding |
|
Control Mode |
PLC Automatic |
|
Intelligent Sensor |
Continuously Feeding with Worker Protection |
|
High Temperature Retention(HTR) |
Yes (Adjustable) |
|
Intelligent Save Fuel Function |
Yes |
|
Primary Combustion Chamber |
1200Liters(1.2m3) |
|
Internal Dimensions |
120x100x100cm |
|
Secondary Chamber |
600L |
|
Smoke Filter Chamber |
Yes |
|
Feed Mode |
Manual |
|
Burner Type |
Italy Brand |
|
Temperature Monitor |
Yes |
|
Temperature Thermometer |
Corundum Probe Tube, 1400℃Rate. |
|
Temperature Protection |
Yes |
|
Automatic Cooling |
Yes |
|
Automatic False Alarm |
Yes |
|
Automatic Protection Operator(APO) |
Yes |
|
Time Setting |
Yes |
|
Progress Display Bar |
3.7 in” LCD Screen |
|
Oil Tank |
200L |
|
Chimney Type |
Stainless Steel 304 |
|
1st. Chamber Temperature |
800℃–1000℃ |
|
2nd. Chamber Temperature |
1000℃-1300℃ |
|
Residency Time |
2.0 Sec. |
|
Gross Weight |
7000kg |
|
External Dimensions |
270x170x190cm(Incinerator Main Body) |
|
Burner operation |
Automatic On/Off |
|
Dry Scrubber |
Optional |
|
Wet Scrubber |
Optional |
|
Top Loading Door |
Optional |
|
Asbestos Mercury Material |
None |
|
Heat Heart Technology(HHT) |
Optional |
|
Dual Fuel Type(Oil&Gas) |
Optional |
|
Dual Control Mode(Manual/Automatic) |
Optional |
|
Temperature Record |
Optional |
|
Enhanced Temperature Thermometer |
Optional |
|
Incinerator Operator PPE Kits |
Optional |
|
Backup Spare Parts Kits |
Optional |
|
Mobile Type |
Optional:Containerized/Trailer/Sledge Optional |
Modular Waste Incineration Systems for Emergency Relief and Epidemic Prevention Centers
Modular Waste Incineration Systems for Emergency Relief and Epidemic Prevention Centers
Governments and health authorities worldwide are strengthening emergency response and epidemic prevention logistics. Central and regional disaster-relief storage centers accumulate large quantities of protective suits, masks, and reagent packaging during disease outbreaks and public health emergencies. The proper disposal of these materials―especially contaminated or expired items―is essential to prevent secondary infection and environmental contamination. The HICLOVER modular incinerator system offers a fast-deployable, high-temperature solution for emergency waste management across Asia, Africa, and Latin America.
The Need for Rapid and Safe Emergency Waste Treatment
During events such as pandemic surges, quarantine operations, or disaster recovery, emergency storage bases and medical logistics warehouses must handle waste quickly and securely. Open burning or conventional landfilling can release pathogens or chemical residues. In regions like Philippines, Kenya, and Saudi Arabia, the establishment of epidemic prevention material depots has highlighted the importance of on-site incineration systems that are both modular and mobile.
HICLOVER addresses these challenges with containerized or skid-mounted modular incineration units, designed for quick installation, easy relocation, and low operational complexity―ideal for emergency deployment scenarios.
HICLOVER Modular Incinerator Features
The HICLOVER modular incinerator integrates a high-efficiency combustion system with automated control and emissions safety. Core features include:
-
Primary combustion chamber (850C950 °C) for general medical and PPE waste.
-
Secondary combustion chamber (≥1100 °C, ≥2 s retention) for complete gas oxidation.
-
PLC automatic control with real-time temperature monitoring.
-
Preassembled modular design for field installation within 24C48 hours.
-
Fuel flexibility: supports diesel, LPG, or natural gas.
-
Optional dry scrubber or activated carbon filtration module for clean exhaust.
-
Containerized structure with anti-corrosion treatment for outdoor or tropical storage.
This configuration ensures complete thermal destruction of infectious and chemical residues while remaining transportable and low-maintenance.
Application in Emergency and Epidemic Management
HICLOVER systems are suitable for:
-
National disease control material reserves and epidemic response warehouses.
-
Regional emergency logistics bases supporting hospitals and field clinics.
-
Mobile quarantine camps and temporary treatment zones during pandemics or disasters.
In countries such as Malaysia, Ethiopia, and Colombia, modular incineration units enable authorities to deploy full waste-treatment capacity within hours, without the need for permanent construction.
Environmental and Operational Advantages
-
Complete sterilization of biological waste and PPE materials.
-
Fast installation and immediate start-up with minimal civil work.
-
Compact and transportable for multi-site use.
-
Reduced risk of cross-contamination in temporary response sites.
-
Compliance with WHO and GB 18484-2020 emission standards.
By combining modular structure with automated control, HICLOVER provides a flexible system for national and regional emergency preparedness, ensuring environmental safety and operational resilience.
Reliable Partner for Emergency and Health Infrastructure
HICLOVER’s technology is trusted globally for containerized and mobile incineration solutions, supporting governments, humanitarian agencies, and health departments in managing high-risk waste efficiently. With experience in over 40 countries, HICLOVER continues to provide modular environmental systems that integrate incineration, filtration, and emission control for critical response applications.
Learn more about available configurations and technical specifications at:
www.hiclover.com | Modular Incinerator Systems | Emergency Waste Solutions | CloverFilter Air Filtration Units | Contact HICLOVER
Keywords: modular incinerator, emergency waste treatment, epidemic prevention equipment disposal, containerized incineration system, PPE waste management, HICLOVER environmental technology, disaster relief waste solution.
2025-11-03/11:15:33
|
Incinerator Items/Model |
HICLOVER TS100(PLC)
|
|
Burn Rate (Average) |
100kg/hour |
|
Feed Capacity(Average) |
150kg/feeding |
|
Control Mode |
PLC Automatic |
|
Intelligent Sensor |
Continuously Feeding with Worker Protection |
|
High Temperature Retention(HTR) |
Yes (Adjustable) |
|
Intelligent Save Fuel Function |
Yes |
|
Primary Combustion Chamber |
1200Liters(1.2m3) |
|
Internal Dimensions |
120x100x100cm |
|
Secondary Chamber |
600L |
|
Smoke Filter Chamber |
Yes |
|
Feed Mode |
Manual |
|
Burner Type |
Italy Brand |
|
Temperature Monitor |
Yes |
|
Temperature Thermometer |
Corundum Probe Tube, 1400℃Rate. |
|
Temperature Protection |
Yes |
|
Automatic Cooling |
Yes |
|
Automatic False Alarm |
Yes |
|
Automatic Protection Operator(APO) |
Yes |
|
Time Setting |
Yes |
|
Progress Display Bar |
3.7 in” LCD Screen |
|
Oil Tank |
200L |
|
Chimney Type |
Stainless Steel 304 |
|
1st. Chamber Temperature |
800℃–1000℃ |
|
2nd. Chamber Temperature |
1000℃-1300℃ |
|
Residency Time |
2.0 Sec. |
|
Gross Weight |
7000kg |
|
External Dimensions |
270x170x190cm(Incinerator Main Body) |
|
Burner operation |
Automatic On/Off |
|
Dry Scrubber |
Optional |
|
Wet Scrubber |
Optional |
|
Top Loading Door |
Optional |
|
Asbestos Mercury Material |
None |
|
Heat Heart Technology(HHT) |
Optional |
|
Dual Fuel Type(Oil&Gas) |
Optional |
|
Dual Control Mode(Manual/Automatic) |
Optional |
|
Temperature Record |
Optional |
|
Enhanced Temperature Thermometer |
Optional |
|
Incinerator Operator PPE Kits |
Optional |
|
Backup Spare Parts Kits |
Optional |
|
Mobile Type |
Optional:Containerized/Trailer/Sledge Optional |
Mobile and Containerized Incinerator Solutions for Kenya’s Referral Hospitals and Emergency Camps
Mobile and Containerized Incinerator Solutions for Kenya’s Referral Hospitals and Emergency Camps
Kenya’s healthcare system and humanitarian operations face growing pressure to manage infectious and hazardous waste safely. With referral hospitals in Nairobi, Kisumu, and Mombasa handling large volumes of medical waste, and with UN emergency camps operating in northern Kenya, there is an urgent need for mobile incinerator solutions that can be rapidly deployed, safely operated, and maintained under demanding conditions. HICLOVER provides internationally recognized incineration technology designed to meet these challenges.
Mobile Incinerator for Kenya Referral Hospitals
A mobile incinerator for Kenya referral hospitals offers flexibility and reliability for facilities that process hundreds of kilograms of medical waste daily. Unlike fixed concrete installations, mobile units can be installed within existing hospital compounds or relocated if required. This mobility is critical in Kenya’s evolving healthcare infrastructure, where regional hospitals must adapt to shifting patient loads and waste generation patterns.
HICLOVER’s incinerators are built with high-capacity combustion chambers, refractory linings, and dual-chamber high-temperature systems to guarantee complete destruction of sharps, plastics, and pathological waste. These units achieve combustion temperatures above 1100°C, reducing waste volume by up to 90% while ensuring emissions remain within international standards.
Containerized Mobile Incinerator for UN Emergency Camps in Kenya
In humanitarian response scenarios, especially in UN-supported refugee settlements in Kakuma and Dadaab, the availability of containerized mobile incinerators for UN emergency camps in Kenya is vital. Containerized designs allow for rapid shipment and installation, often within 24C48 hours. These self-contained units arrive pre-assembled in ISO shipping containers, complete with burners, chimneys, control systems, and optional wet scrubber units.
This format ensures that NGOs and international aid agencies can deploy robust waste treatment systems directly to field locations, minimizing logistical complexity and ensuring safe disposal of infectious materials under crisis conditions.
Humanitarian Relief Incinerator Supply for Kenya and Uganda
Cross-border emergency operations often require standardized solutions. Kenya humanitarian relief incinerator for emergency response programs frequently extend into Uganda, where refugee camps and remote hospitals face the same waste management challenges. HICLOVER has supplied multiple incinerators to humanitarian projects across Africa, offering plug-and-play systems with diesel or LPG burners, PLC automation, and integrated safety sensors for reliable operation in remote conditions.
These systems are particularly relevant for donor-funded projects where transparency, performance, and compliance with WHO and UNEP guidelines are mandatory.
HICLOVER Model TS300: A Containerized Solution for East Africa
The HICLOVER TS300 incinerator is an excellent example of a system adapted for East African conditions:
-
Burn rate: 250C300 kg/hour, ideal for referral hospitals and large camps.
-
Containerized design: pre-installed in a 20ft or 40ft ISO container, ready for transport and field deployment.
-
PLC-controlled system: automated burner ignition, air distribution, and temperature monitoring.
-
Secondary combustion chamber: guarantees minimum 2-second flue gas retention at 1100°C for dioxin control.
-
Optional wet scrubber and filtration: ensures emissions meet strict donor project requirements.
Conclusion
From mobile incinerators for Kenya referral hospitals to containerized mobile incinerators for UN emergency camps, HICLOVER provides sustainable, practical solutions for East Africa’s healthcare and humanitarian sectors. The deployment of Kenya humanitarian relief incinerators for emergency response ensures that both hospitals and aid organizations can manage medical waste safely, efficiently, and in compliance with international standards.
For more information on containerized and mobile models such as the HICLOVER TS300, visit www.hiclover.com or contact [email protected].
mobile incinerator for kenya referral hospitals,containerized mobile incinerator for un emergency camps kenya,kenya humanitarian relief incinerator for emergency response